Item Number: 810-00068-008
Description: PM13+ Module 28 T1 to T3/STS-1 Multiplexer for EXM II -48V
Manufacturer: Telco Systems
Please login to see pricing and availability
The EXchange Mux II Advanced
Multiplexer takes multiplexing to a
new level. Connect your T1s or E1s into an
EXchange Mux II and transport them in an
OC-3 or an STM-1. Universal modules slots
provide maximum flexibility to meet any
application.
The low power consumption and small
footprint make it ideal for collocation
applications. Redundancy for all modules
provide added reliability. Integrated T1/E1
testing makes fault isolation routine; and
unlike most M13 muxes, T1/E1 framing
information is included to provide additional
performance statistics.
Specifications
OC-3/STM-1 INTERFACE
Line Rate: 155.52 Mbps +/- 20ppm
Output Power (IR): -8 dbm to -15 dbm
Input Sensitivity (IR): -29 dbm
Output Power (LR): 0 dbm to -5 dbm
Input Sensitivity (LR): -32 dbm
Optical Connector: LC
Optical Cable: Single-mode 1310 nm or
1550 nm
T3 INTERFACE
Line Rate: 44.736 Mbps +/- 20ppm
Line Format: Bipolar B3ZS encoded
Framing: C-Bit Parity or M13
Line Build-Out: 0-900 feet
Input Level: 35mV to 900mV
Clocking: Loop or Internal Timed
STS-1/AU3 INTERFACE
Line Rate: 51.84 Mbps +/- 20ppm
Line Format: Bipolar B3ZS encoded
Payload Mapping: Asynchronous T1/E1/T3
Line Build-Out: 0-900 feet of cable
Input Level: 35mV to 900mV
Clocking: Loop or Internal Timed
T1 INTERFACE
Line Rate: TX: 1.544 Mbps +/- 50 ppm
RX: 1.544 Mbps +/- 130
ppm
Line Code: AMI or B8ZS
Line Build-Out: 0 to 655 ft.
Line Framing: SF (D4), ESF, or Unframed
E1 INTERFACE
Line Rate: 2.048 Mbps +/- 50 ppm
Line Code: AMI or HDB3
Line Framing: Framed, Unframed
PHYSICAL LINE INTERFACES
M13/PM13/PM13E Modules
2RU: T1/E1: Dual 68-pin SCSI
STS-1/DS3: Dual BNC
3RU: T1/E1: Dual 64-pin Champ
STS-1/DS3: Dual BNC
OMX3/OMXT3/OMUX3 Modules
2RU: Optical Connector: LC
STS-1/DS3: 6 SMA
3RU: Optical Connector: LC
STS-1/DS3: 6 BNC
PERFORMANCE MONITORING
Cumulative Errored Seconds:
• T1/E1 BPV • T1/E1 Frame Bit errors
• T1/E1 CRC errors • T3 P-bit errors
• T3 CP-bit errors • T3 FEBE errors
• STS-1 Section (B1) errors • VT1.5 Parity errors
• STS-1 Line (B2) errors • VT2 Parity errors
ALARMS
• External contacts for visual and audible alarms
• Major and Minor Alarms
• Normally open or normally closed
• Front panel alarm cutoff
TESTABILITY
• T3, STS-1, AU3 and OC-3 Loopbacks
• Remote C-bit loopback (for T3)
• T1/E1 Loopbacks (toward T1/E1 drop and/or
T3/STS-1/AU3 line)
• T1 Inband Loopbacks (Gen & Rec)
• Manual and Automatic Protection switching for
high and low speed circuits
• T1/E1 Test Patterns (Gen & Rec)
• T1/E1 Front Panel Monitor
SYSTEM MANAGEMENT
• VT100 terminal
• Telnet
• SNMP (Fully-compliant Charles Industries MIB)
• Web Browser
• TL-1
• Serial interface, 1200 baud to 115 kilobaud
• Ethernet 10BaseT, RJ45 Connector
• Remote management via SONET DCC
CERTIFICATIONS
• UL/C-UL
• FCC Part 15
• NEBS Level 3
• CE Mark
MECHANICAL
19” Shelf: 10 service module slots (5 pairs)
2RU: 3.5” H x 17.37” W x 12” D
3RU: 5.25” H x 17.37” W x 12” D
Maximum of 20 lbs.
(fully loaded and redundant)
23” Shelf: 14 service module slots (7 pairs)
2RU: 3.5” H x 21” W x 12” D
3RU: 5.25” H x 21” W x 12” D
Maximum of 25 lbs.
(fully loaded and redundant)
ENVIRONMENTAL
• Ambient operating temperature from 0º to 45º C
• Relative humidity to 95% (non-condensing)
POWER
• Separate A & B battery feeds
• -48VDC or +24VDC, 118 watts (23” shelf) or 90
watts
(19” shelf) maximum